Breath Well Medical Systems
Breath Well Medical Systems
Konanakunte, Bengaluru, Karnataka
GST No. 29ABOPU7704Q1ZH

BIPAP Machine

We are a leading Wholesale Trader of resmed floton st 25 - bipap machine and resmed aircurv 10 vauto auto bipap from Bengaluru, India.
Request CallBack
  • Resmed Floton ST 25  - BIPAP MACHINE
  • Resmed Floton ST 25  - BIPAP MACHINE
Resmed Floton ST 25  - BIPAP MACHINE
Get Best Quote

Resmed Floton ST 25 - BIPAP MACHINE

Approx. Price: Rs 51,500 / NumberGet Latest Price
Product Brochure
Product Details:
Minimum Order Quantity1 Number
ModesS/T
Usage/ApplicationClinic
Pressure RangeIPAP 4 - 25 cm H2O
UsageHospital,Clinic,Personal, Clinic, Hospital
ModelST 25
Size180mmX210X105mm
BrandResMed

Dimensions 180 mm Lx210 mmW x105 mmH Weight 1.6Kg (1.2Kg without humidifier) IPAP range 4 -20 cmH2O (ST20), 4 -25 cmH2O (ST25) 4 -30 cmH2O (ST30), 4 -33 cmH2O (ST33) EPAP range 4cm H2O - 20cm H2O CPAP range 4cm H2O - 20cm H2O Pressure accuracy +-(2% of the full scale reading + 4% of the actual read) Ramp Time 0 - 60 min, 1min per step Noise


Additional Information:
  • Item Code: F201
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),D/P
  • Port of Dispatch: 1 DAY
  • Production Capacity: 1 DAY
  • Delivery Time: 1 HRS
  • Packaging Details: BOX
Yes! I am interested
Request CallBack
Resmed AirCurv 10 VAuto  AUTO BIPAP
Get Best Quote

Resmed AirCurv 10 VAuto AUTO BIPAP

Approx. Price: Rs 80,000 / NumberGet Latest Price
Product Brochure
Product Details:
BrandResmed
ModesS
Usage/ApplicationHospital
Specifications
Height116 mm
Weight1248 gm
Breadth150 mm
Length255 mm
Sound pressure level
Supplemental oxygen Maximum flow15 L/min (CPAP, S); 4 L/min (VAuto)
Storage and transport humidity5 to 95%relative humidity, non-condensing
Ramp TimeYou can set your Ramp Time to Off or between 5 to 45 minutes.
Water capacity:To maximum fill line 380 mL
Air outlet22 mm
Typical power consumption53W (57VA)
SensorsPressure sensor: Internally located at device outlet, analoguegauge pressure type, -5 to +45cmH2O (-5 to +45 hPa); Flow sensor:Internally located at device inlet, digital mass flow type, -70 to +180 L/min
Operating altitudeSea level to 2,591m; air pressure range 1013hPa to 738 hPa
Maximum single fault steady state pressureDevice will shut down in the presence of a single fault if the steady state pressure exceeds:30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec
ModesS, VAuto, CPAP
Sound power levelPressure level measured according to EN ISO 17510-1:2009 (CPAP mode):SlimLine:26.6 dBA with uncertainty of 2 dBAStandard:26.6 dBA with uncertainty of 2 dBAPower level measured according to EN ISO 17510-1:2009 (CPAP mode):SlimLine:34.6 dBA with uncertainty of 2 dBAStandard:34.6 dBA with uncertainty of 2 dBADeclared dual-number noise emission values in accordance with ISO4871:1996.
Peak power consumption104W (108VA)
Operating pressure rangeS, VAuto: 2 to 25cm H2O (2 to 25 hPa); CPAP: 4 to 20cmH2O (4 to 20 hPa)
Power supply unit90W power supply unit; AC input range:100–240V, 50–60Hz 1.0–1.5A, Class II115V, 400Hz 1.5A, Class II (nominal for aircraft use); DC output:24V 3.75A
Storage and transport temperature-20°C to +60°C
Operating humidity10 to 95% relative humidity, non-condensin
Housing constructionFlame retardant engineering thermoplastic
Operating temperature+5°C to +35°C Note: The air flow for breathing produced by this therapy device can be higher than the temperature of the room. Under extreme ambient temperature conditions (40°C) the device remains safe.
Wireless ModuleTechnology used:4G, 2G. It is recommended that the device is a minimum distance of 2 cm from the body during operation. Not applicable to masks, tubes or accessories. Technology may not be available in all regions