Breath Well Medical Systems
Breath Well Medical Systems
Konanakunte, Bengaluru, Karnataka
GST No. 29ABOPU7704Q1ZH

Post Operative Ventilator

Our product range includes a wide range of resmed astral 150 non-invasive ventilator.
Request CallBack
Resmed Astral 150 non-invasive ventilator
Get Best Quote

Resmed Astral 150 non-invasive ventilator

Approx. Price: Rs 6.5 Lakh / NumberGet Latest Price
Product Brochure
Product Details:
Model Name/Number27083
Usage/ApplicationICU
TypeDigital
BrandRESMED
Key Features - 
  • Invasive and non invasive, adult to peadiatric usage
  • In built battery back up of upto 8 hours, which can be extended upto 24 hours with external battery pack
  • 4 customizable pre set programs
  • Single limb circuit with leak and valve ventilation
  • Dual limb circuit
  • Apnoea Ventilation
  • Manual breath
  • Sigh Breath
  • Optional SpO2  monitoring
  • FiO2 monitoring
  • 7 days of high resolution data with 25Hz pressure and flow
  • 365 days of summary data
  • Wide range of settable alarms, including SpO2 and FiO2,when connected

 

Specifications
Height 93 mm
Weight 3.2 kg
Breadth 215 mm
Length 285 mm
Sound pressure level 35 ± 3 dBA as measured according to ISO80601-2-12:2011.
Maximum single fault steady pressure 60 hPa (in all modes)
Breathing resistance under single fault Paediatric circuit Inspiration: 2.2 hPa (at 15 L/min), 5.3 hPa (at 30 L/min) Expiration: 2.4 hPa (at 15 L/min), 5.0 hPa (at 30 L/min) Adult circuit Inspiration: 5.7 hPa (at 30 L/min), 8.3 hPa (at 60 L/min) Expiration: 4.2 hPa (at 30 L/min), 6.2 hPa (at 60 L/min)
Max Flow 220 L/min
Operating pressure range Single limb with valve or double limb with valve: 3 to 50 hPa Single limb with intentional leak: 2 to 50 hPa CPAP: 3 to 20 hPa Maximum working pressure limit: 10 to 55 hPa Forced cycling occurs if the Pressure alarm limit is exceeded
IEC 60601-1 Class II double insulation Type BF Continuous operation Suitable for use with oxygen.
Pressure measurement Internally mounted pressure transducers
Data storage 7 days of high-resolution airway pressure, respiratory flow and delivered volume (sampled at 25 Hz). 7 days of breath-related therapy data (sampled at 1 Hz). 365 days of statistical data per program
Circuit resistance and compliance range for stated accuracy of monitoring and control** Paediatric patient setting: Circuit resistance range (circuit with intentional leak): 0 to 8 hPa at 60 L/min Circuit resistance range (circuit with valve): 0 to 20 hPa at 60 L/min Circuit compliance range: 0 to 4 mL / hPa Adult patient setting: Circuit resistance range (circuit with intentional leak): 0 to 20 hPa at 120 L/min Circuit resistance range (circuit with valve): 0 to 35 hPa at 120 L/min Circuit compliance range: 0 to 4 mL / hPa
Modes Valve Circuit Therapy: CPAP, ACV, PACV, P-SIMV, V-SIMV, PAC Leak Circuit Therapy: CPAP, ST, PAC, iVAPS with iBR and optional Auto EPAP
Internal Battery Lithium-Ion battery, 14.4 V, 6.6 Ah, 95 Wh Operating hours (best case): 8 h with a new battery under normal conditions (see below). Test conditions: Adult, P(A)CV mode, P control: 20 cmH2O, PEEP: Off, Rate: 15 bpm, Ti: 1.2 sec. Note: Time may vary with environmental conditions. Total lifetime: 3,000 hours of operation on internal battery Operating hours (worst case) > 4 hour run time under the following conditions: Test conditions: Adult, non-vented, PACV mode, Double limb circuit, Pressure Assist = 30 cmH2O, PEEP = 20 cmH2O Rate:20 bpm, Ti: 1.0 sec, Rise Time = Off, Safety Vt = off, Trig = Off. All other parameters remain at default settings.
Power supply unit AC 100–240V, 50–60Hz, 90 W 3.75 A continuous, 120 W / 5A peak 110V/400 Hz
Operating tidal volume range (volume control modes) Flame retardant engineering thermoplastic




Yes! I am interested